Sonel CMP-1010 Multifunctional AC/DC Clamp Meter for downstream of Frequency Converters

Request Quote

Datasheet

SKU: WMGBCMP1010 Categories: , , Brand: Sonel

Description

  • The Sonel CMP-1010 measures AC and DC current, AC and DC voltage and more. The meter provides precise measurements downstream of frequency converters. The device is versatile due to many measurement options, including low-impedance voltage measurement (Low Z). Darkness in the workplace is not a problem thanks to the built-in flashlight.

    Technical specifications

    Measurement functions Range Resolution Accuracy
    AC current up to 1000 A from 0.1 A from ±(2.5% m.v. + 8 digits)
    DC current up to 1000 A from 0.1 A from ±(2.5% m.v. + 5 digits)
    AC voltage up to 1000 V from 0.001 V ±(1.5% m.v. + 5 digits)
    DC voltage up to 1000 V from 0.1 mV from ±(0.5% m.v. + 5 digits)
    Low Z up to 300.0 V from 0.001 V ±(3.0% m.v. + 40 digits)
    Resistance up to 60.00 MΩ from 0.1 Ω from ±(1.0% m.v. + 4 digits)
    Frequency up to 99.99 kHz from 0.001 Hz ±(1.2% m.v. + 5 digits)
    Capacitance up to 100.0 mF from 0.01 nF from ±(3.0% m.v. + 5 digits)
    Duty cycle (%) 10.0…90.0% 0.1% ±(1.2% m.v. + 2 digits)
    Temperature measurement -20.0…+1000ºC
    -4.0…+1832ºF
    0.1ºC
    0.1ºF
    ±(3% m.v. + 5ºC)
    ±(3% m.v. + 9ºF)
    Continuity / Diode test ✓ / ✓

    Modern clamp

    The innovative shape means easier access in hard to reach and tight places. The clamp edging is equipped with a contactless voltage indicator sensor.

    Visibility in any conditions

    Darkness in the workplace is not a problem thanks to the built-in flashlight.

    Multifunctional

    The device is versatile due to many measurement options. In addition to the basic measurements, the instrument has special functions, including inrush current (INRUSH), max / min peak values (Peak MAX/Peak MIN), relative value (REL), low-impedance voltage measurement (Low Z).

    Robust design

    With the help of the latest technologies, a compact instrument for working in the toughest conditions has been created. The rubber housing protects the device against accidental damage.

    Measurement of converters

    The meter provides precise measurements downstream of frequency converters thanks to the VFD function.